zonal_harmonic_field_solver (in electromagnet_field)
uses the zonal harmonic expansion about an axis to compute fields. only valid if the symmetry parameter is set to axial.
<zonal_harmonic_field_solver>KZonalHarmonicMagnetostaticFieldSolverAttribute |
Type |
Description |
|---|---|---|
|
|
ending z value for the central set of source points. |
|
|
|
|
|
in all cases the spacing in meters between central source points will be at least this. |
|
|
starting z value for the central set of source points. |
|
|
|
|
|
the series is declared converged when the sum of latest five terms divided by the entire sum is less than this ratio. |
|
|
an expansion will not be attempted when the distance from the field point to the nearest source point divided by that source point’s convergence radius exceeds this ratio. |
|
|
controls the number of times the surface container is recursively split. each split at each level results in an independent zonal harmonic expansion. |
|
|
the number of central coefficients to store per source point. |
|
|
the number of remote coefficients to store per source point. |
|
|
|
|
|
an expansion will include a single term with no convergence check when the distance from the field point to the nearest source point divided by that source point’s convergence radius is less than this ratio. |
|
|
ending z value for the remote set of source points. |
|
|
starting z value for the remote set of source points. |
|
|
|
|
|
if true, the distance from one source point to the next will be computed using a fraction of the previous source point’s convergence radius. |
Example:
<zonal_harmonic_field_solver
number_of_bifurcations="-1"
convergence_ratio=".99"
convergence_parameter="1.e-15"
proximity_to_sourcepoint="1.e-12"
number_of_central_coefficients="500"
use_fractional_central_sourcepoint_spacing="false"
central_sourcepoint_spacing="2.e-6"
central_sourcepoint_start="-3.3e-3"
central_sourcepoint_end="3.3e-3"
number_of_remote_coefficients="200"
remote_sourcepoint_start="-1.e-1"
remote_sourcepoint_end="1.e-1"
/>
Used as:
<zonal_harmonic_field_solver>in <electromagnet_field>
More information
Appears in the documentation:
Fields (Magnetic fields)
Used in example configurations: